Parison Stretching: PSM 500-SD

Parison stretching is integral to the balloon blowing process, and Medical Production Technology Europe BV has applied its innovative design expertise to develop the PSM-500-SD parison stretching machine. Designed to be used in conjunction with the MPT BFM-500-S2 and BFMS-500-S2 Balloon Forming Machines, the PSM-500-SD utilizes split die technology to deliver optimal stretching results while addressing the limitations of currently available machines.

Fully servo-controlled, the PSM-500-SD stretches parisons with forces up to 500 N. A precise, easy-to-use sensor system enables well-defined secondary stretch for consistent, repeatable parisons, with recipe-based control managing all parameters.

An innovative pre-heating system prevents the stretching dies from damaging the parison material before or during stretching, preventing die pollution and eliminating associated production downtime and rejected products.

Stretching dies can be easily removed and replaced with dies of different dimensions, and we can quickly produce highly polished custom dies to meet specific dimensional requirements.

Built to the high-quality standards and design philosophy of Medical Production Technology Europe BV, the PSM-500-SD is a reliable, precise solution for demanding parison-forming applications.

Stent Crimping: CR-120A

The CR-120A Stent Crimping Machine is developed for the crimping and transfer into the delivery system of self-expandable stents up to 120 mm in length with a maximum diameter of approx. 20 mm.

Tools: Tipping Dies & Hole Forming Drills

Catheter Hole Punching DrillsFlow-Thru™ Catheter Hole Forming Drill Bits

Attain the highest quality hole appearance and reduce manufacturing costs. Enjoy fast throughput and infrequent drill bit changes.

Benefit from CATHTIP’s proprietary Flow Thru™ hollow design drills in your high volume production environment. The ground edge and the exact geometry of the drills make holes that are rounded on the outside and burr free on the inside.

Catheter Tipping DiesCatheter Dies for Tipping, Bonding, Flaring

To ensure your catheter device is manufactured to your exacting geometry AND without flash, CATHTIP has perfected proprietary die technology. Our customers enjoy extended production life and optimal RF-induction response with CATHTIP’s superior catheter tipping dies made from high-density carbide.

We also offer alternate materials, such as stainless steel and nickel, and 3D-printed, high-temperature plastic or ceramic for proof-of-concept, rapid prototyping or R&D purposes.

Flow Thru™ Hollow Drills
Cores flow through drill bit to be captured in filter chamber: work area is kept free of hole cores.

Hardened Steel with Titanium Nitride Coating
Long life cutting through polymers containing abrasive BaSO4, TiO2, and Silica.

Down to .0018″ wall thickness
Minimal plastic cold flow around holes.

Stiff Cutting Tip and High Concentricity
No scuff marks at hole entry and no bending or vibration during drilling.

Extremely Sharp Cutting Edge
Clean cut at hole exit.

Better Catheter Hole Drilling
The catheter hole cores travel from the drill bits and continue their isolation as they flow directly into a collection chamber.

Ground Edge
The fine sharpness of the drills is achieved by grinding with very fine grit wheels. This allows the drill to cut cleanly with minimal resistance. Our attention to detail serves your catheter hole drilling production needs and gives you a better product. Ask us about drill resharpening services.

Catheter Tipping Dies

Need sample parts for proof-of-concept? With our extensive library of over 400 dies, we can often produce a close approximation of your catheter design, whether you need simple tip forming, complex tip forming, flaring, flanging, or bonding.

Rapid prototyping? We’ll manufacture a die to your specific geometry, incorporating CATHTIP® proprietary design features, to quickly produce a prototype.

Process refinement? Take the prototype to the next level to prepare your device for production. Additionally, CATHTIP can take your existing product and improve upon your current process to deliver flashless tipping and more exacting geometry.

Testing samples? We supply engineering samples for qualification studies.

Part quality waning? Clean your die or replace them entirely!

 

Catheter Tipping: Magnum

The Magnum provides the most flexible RF architecture on the market, capable of tip forming, flaring, and bonding in R&D or production settings. Our state-of-the-art, precision catheter forming systems produce the highest quality parts with speed and consistency. Achieve flashless tips, smooth bonds, and exacting geometry with virtually all thermo-plastic materials. Produce a wide range of applications – flares, flanges, angular welds, bonds, multi-lumen shape transitions, butt welds, balloon to catheter welds, neck downs, soft-tip fusion, metal-to-tube adhering, sheaths, dilators, radio-opaque, strain relief bonds, swaged metal needle guides, tube-in-tube bonds, etc.

Catheter Tipping: Quantum

The Cathtip Quantum is a tabletop tipping machine designed to deliver the superior output expected of the CATHTIP standard. Our state-of-the-art, precision catheter-forming systems produce high-quality parts quickly and consistently. Achieve flashless tips, smooth bonds, and exacting geometry with virtually all thermoplastic materials. Produce a wide range of applications – flares, flanges, angular welds, bonds, multi-lumen shape transitions, butt welds, balloon-to-catheter welds, neck downs, soft-tip fusion, metal-to-tube adhering, sheaths, dilators, radiopaque, strain relief bonds, swaged metal needle guides, tube-in-tube bonds, etc.

Coil Winder: 503 Single Filar

EBD Coil winding technology is developed specifically to wind micro coils for minimally invasive medical devices. Delivers the ability to wind coils using filament as small as .001″ diameter on a .004″ mandrel using our innovative closed-loop filar tension control system. The machine flexibility enables the filar tension to be recipe controlled from 5 grams to 600 grams during the entire wind.

The picture above reflects this technology from our modular multi-filar systems. Each multi-filar platform can produce catheter coils using one, all, or somewhere in between the filar heads, you define for your machine.

The above picture shows a coil on the tip of Lincoln’s nose, on a penny, alongside a human hair at the right. Coils length and filar count are only limited by your facility floor space.

924 Coil Winder: Multi Filar

The Engineering By Design 924 Multi-Filament Coil Winder machine uses a vision system to wind fine filaments around a spinning mandrel and produce multi-filar micro coils with up to 4 filaments. EBD coil winders deliver exacting control of all winding parameters, with programmable filament tension that achieves tight precision down to extremely low values.

Wind filaments as small as .001 inch diameter wire using our innovative closed-loop filar tension control system.

The coil in the second image was formed by winding 12 individual wires, each .0045 inch in diameter, over a .035 inch diameter spinning mandrel.

Liner Stretcher

The CATH-TECH™ Liner Stretcher uses a combination of heat and tension to process a liner onto a fixed mandrel. This automated process eliminates the need for operators to hand-stretch a liner.

Our CT-Liner Stretcher and its process allow the liner to sit tight against the mandrel with minimal relaxation. Because of fine machine control combined with the process, throughput increases, scraped units decrease, and etching issues (“white liner”) diminish. This process also eliminates operator safety and health issues related to carpal tunnel syndrome.

Flexible Stent Crimping: CR-240-FSCP

The CR-240-FSCP Flexible Stent Crimping Platform is developed for the crimping and transfer on or into the delivery system. Both balloon expandable and self- expandable stents up to 220 mm length can be handled.

CR-240-SA Stent Crimping Machine

The CR-240-SA Stent Crimping Machine is developed for the crimp and transfer of self-expandable stents into delivery systems in a single, controlled process. It accommodates stents up to 200 mm in length with a maximum diameter of approximately 30 mm, supporting consistent handling of larger, more complex devices.